Wall mounting mechanical room humidistats, Universal use

Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning
Din rail mounting miniature humidistat for electrical cabinets
Main Application: condensation in electrical enclosures and cabinets can be critical for electrical components and safety. This humidistat is designed to switch on a heater or a ventilating fan when the relative humidity raises at dangerous levels, when there is a risk to reach the dew point usually around 65%.
Weight | 0.5 kg |
---|---|
Dimensions | 67 × 31 × 50 mm |
Maximum setting (%RH) | |
Minimum setting (%RH) | |
Measuring accuracy (%RH) | |
Differential at 50% RH | |
Electrical rating | |
Voltage | |
Min operating temperature (°C) | |
Max operating temperature (°C) | |
Min storage temperature (°C) | |
Max storage temperature (°C) | |
Ingress protection |
Description
MAIN FEATURES
Main Application: condensation in electrical enclosures and cabinets can be critical for electrical components and safety. This humidistat is designed to switch on a heater or a ventilating fan when the relative humidity raises at dangerous levels, when there is a risk to reach the dew point usually around 65%.
It can also be used to switch on humidifiers, dehumidifiers, or other devices.
Humidity sensing element: hygroscopic polymer film with special treatment, produced by Ultimheat, ensuring a fast response, long life and high stability
Setting range: 35 to 95% RH
Measuring accuracy: ±5% RH
Differential at 50% RH: 8% RH (±3% RH )
Measuring medium: air, pressure-less, non-aggressive
Electrical contact: silver contacts, SPDT, 5A 250V
Connection: 3 screw terminals for 1.5mm² wires, max torque 0.5Nm
Mounting: clip for 35mm DIN rail EN50022
Operating temperature: 0 to+60°C (+32 to +140F)
Storage temperature: -20 to +70°C (-4 to +158F)
Mounting position: vertical
Voltage supply: the humidistat should be mounted such that there is no buildup of condensate on or in the device. If the voltage supply is higher than 48V thereisarisk ofvoltagearcing in theeventofwatercondensation on the micro-switch or connecting terminals which might destroy the control.
Ingress protection class: IP30
Dimension: 67x50x 36mm
Maintenance: The humidity sensing ribbon is maintenance-free in clean air. Air containing solvent can cause measuring errors and failure, depending on the type and concentration. Deposits such as resin aerosols, lacquer aerosols, smokes, which eventually form a water-repellent film are harmful for the measuring element.
DIMENSIONS
Wiring diagram
![]() Dehumidification |
![]() Humidification |
![]() Dehumidification fan |
Technical specifications sheet
TO ACCESS DOWNLOAD DOCUMENTS, PLEASE LOGIN/REGISTER. DATASHEET, DRAWINGS (.DWG), 3D MODELS (.STP) AND OTHER DOCUMENTS ARE AVAILABLE.SIMILAR PRODUCTS
-
Wall mounting temperature sensor enclosure, In PA66 and PC, Y3F1
- Features a sealed sensor cable exit system at the top - Includes mounting bosses for printed circuit boards - Includes mounting holes for a 4-20mA temperature converter - Includes two wall brackets - Includes a removable 2.5mm² 6-way terminal block - Output by two M20 cable glands
-
Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning
Main Application: This device is a combination of a humidistat and a room thermostat. It is especially suited for use in air conditioning control of indoor swimming-pool halls.His aesthetics and small size housing (122x70x31mm) allows mounting in most of these applications, but must be protected from splashing water, and used only in ambient air free…
-
Very high temperature ceramic terminal blocks (500°C)
€3.95 – €7.50These high quality electrical connection blocks allow efficient and easy wiring connections of ovens, infrared heaters, quartz tube heaters in furnaces, kilns, catering equipment, but also in equipment that must withstand fire whilst maintaining their function such as road and railway tunnels and military equipment