Paddle flow switches, reed switch contact, external body

Paddle flow switches, reed switch contact, built-in 16A SPDT relay
Paddle flow switches, reed switch contact, external brass body
Main uses: General application in flow detection. . Recommended mounting position is on horizontal pipes, but can be mounted in any position. For liquids flow detection on dia. 15 to 100 mm pipes. Body and union nut in brass for improved mechanical strength and pressure resistance. Connection box with terminal block or connectors, and detection point adjustment screw
Flow sensing | |
---|---|
Main housing material | |
Paddle material | |
Mounting position | |
Mounting type | |
Voltage | |
Electrical rating | |
Ingress protection | |
Electrical connection type | connection box with M16x1.5 cable gland, connection box with 4 pins, M12x1 IEC947-5-2 connector, connection box with DIN 43650-A connector |
Maximum flow detection (L/min) | |
Minimum flow detection (L/min) | |
Calibration (gr) | |
Nominal pressure at 20°C | |
Max operating temperature (°C) | |
Liquids temperature range (°C) |
Description
Size and pressure | Flow sensing:
cleavable paddle |
Mounting:
¾” BSPP Brass Union nut |
Contact:
Reed switch, close on |
Electrical rating | Mounting position | Type |
PN25 | ![]() |
![]() |
![]() |
![]() |
![]() |
R1V |
DN≥15 |
Dimensions
![]()
|
Main uses: General application in flow detection. . Recommended mounting position is on horizontal pipes, but can be mounted in any position. For liquids flow detection on dia. 15 to 100 mm pipes. Body and union nut in brass for improved mechanical strength and pressure resistance. Connection box with terminal block or connectors, and detection point adjustment screw
Functional principle: Balanced magnetic paddle mounted perpendicular to the flow and activating a reed switch through the wall. The return of the paddle is by made by magnetic action, without spring. No seal or liquid can pass between the piping system and the electrical contact. Usable for industrial applications in non-corrosive liquids. Must not to be used for liquids containing magnetic particles or high viscosity liquids, which block the movement of the pallet.
Adjustment:
- By cleaving the paddle
- Fine adjustment by screw driver on internal dial
Paddle shaft: Titanium, providing an outstanding corrosion resistance, and improved mechanical live
Main housing material: Brass
Paddle: Polypropylene, 15 mm width, with 4 sections, numbered 1 to 4, can be cleaved for adjustment to pipe size
Pipe mounting: Nickel plated brass union nut,¾ BSPP, mounting on ¾ BSPP male thread with gasket.
Recommended torque: 10±1 Nm Gasket: NBR
Electrical rating: Max 1A, Max 70W, Max 250V, resistive load. Use on inductive circuits reduces electrical rating. We recommend to protect the reed switch with contact protection device when used in inductive loads
Electric contact type: Normally open, closes by flow rise
Liquids compatibility: For use with clean water and liquids without magnetic particles and without chemical incompatibility with brass, PPO and titanium
Nominal pressure at 20°C: 2,5 MPa (PN25)
Liquids temperature range: 5 to 100°C (Do not withstand water freez- ing inside pipe)
Ambient temperature range: 5 to 80°C
Ingress protection: IP65
Calibration tolerances: +/-15% (on paddle operating force at end of paddle 1)
Electrical connection:
Standard:
IP64 connection box, with screw terminal connection block, M16x1.5 ISO cable gland
Options:
- Connection box with EN17530-803-A (DIN43650-A) connector
- Connection box with IEC947-5-2 M12x1 4 pins connector
Installation instructions:
- Check carefully the paddle orientation: The arrow on housing must be exactly parallel to the pipe
- A 5 mm minimum gap must be respected between end of the paddle and tube wall opposite to the
- We recommend the use of nozzles of length less than or equal to 18 mm between the gasket seat and the inside of the tube and with an inner diameter greater than or equal to 5 mm, to avoid blocking of the paddle.
Accessories: 3/4” male PVC saddles for DN40 to DN100 (OD) PVC pipes, and other fittings: see last section of this catalogue
Important notice: In the case of plastic pipes (PVC, PE), the DN (nominal diameter) corresponds to the outside diameter and wall thickness is variable depending on the application. This must be taken into account to avoid blocking the paddle. In the case of metal pipes, the inner diameter corresponds to the DN. Flow values data are for tubes whose internal diameter corresponds to DN.
Pipe mounting configurations
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Average Flow detection values (Liters/min)
Paddle length |
Pipe ID (mm) | |||||||||||||||
15 | 20 | 25 | 32 | 40 | 50 | 63 | 100 | |||||||||
*Close | **Open | *Close | **Open | *Close | **Open | *Close | **Open | *Close | **Open | *Close | **Open | *Close | **Open | *Close | **Open | |
1-m | 2,7 | 2,3 | 4,8 | 4,5 | 13 | 11 | 22 | 20 | 38 | 35 | 67 | 47 | 167 | 112 | 472 | 317 |
1-H | 4,3 | 3,3 | 7,3 | 6,5 | 18 | 17 | 29 | 27 | 53 | 48 | 83 | 72 | 218 | 142 | 616 | 401 |
1-M | 5,5 | 3,2 | 14 | 12 | 25 | 22 | 38 | 35 | 67 | 60 | 132 | 108 | 262 | 202 | 740 | 571 |
1+2-m | 20 | 18 | 37 | 32 | 68 | 52 | 192 | 155 | ||||||||
1+2-H | 30 | 28 | 53 | 43 | 88 | 72 | 248 | 203 | ||||||||
1+2-M | 40 | 37 | 67 | 63 | 123 | 115 | 347 | 324 | ||||||||
1~3-m | 22 | 20 | 37 | 33 | 125 | 108 | ||||||||||
1~3-H | 34 | 32 | 63 | 50 | 176 | 165 | ||||||||||
1~3-M | 46 | 43 | 77 | 73 | 233 | 217 | ||||||||||
1~4-m | 27 | 24 | 88 | 72 | ||||||||||||
1~4-H | 43 | 40 | 140 | 132 | ||||||||||||
1~4-M | 58 | 55 | 180 | 167 | ||||||||||||
m= calibration at min span
H= calibration at Half span M= calibration at Max span |
* Close by flow rise (L/min) of contact open at no flow position
** Open by flow decrease (L/min) of contact open at no flow position. Average values for indication only. Standard tolerances ±15% |
Main references (With type A cleavable paddle)
Calibration
(Calibration force ±15%, measured at end of paddle N°1) |
Waterproof connection box with M16x1.5 cable gland |
Waterproof connection box with 4 pins, M12x1
IEC947-5-2 connector |
Waterproof connection box with DIN 43650-A connector |
Low span end: 3gr | R1V636680G35N00C | R1V636680G35N00L | R1V636680G35N00D |
Middle span:7gr | R1V676680G35N00C | R1V676680G35N00L | R1V676680G35N00D |
High span end:14 gr | R1V6E6680G35N00C | R1V6E6680G35N00L | R1V6E6680G35N00D |
Other paddles (Non cleavable models)
![]() |
![]() |
![]() |
![]() |
Paddle type B | Paddle type C | Paddle type D | Paddle type E |
Replace 6680 in reference by 1234 | Replace 6680 in reference by 1549 | Replace 6680 in reference by 1564 | Replace 6680 in reference by 1579 |
Consult us for flow detection values with these paddles. OEM paddles can be made on order (MOQ apply)
Technical specifications sheet
TO ACCESS DOWNLOAD DOCUMENTS, PLEASE LOGIN/REGISTER. DATASHEET, DRAWINGS (.DWG), 3D MODELS (.STP) AND OTHER DOCUMENTS ARE AVAILABLE.SIMILAR PRODUCTS
-
Paddle flow switches, reed switch contact, 1/2” male thread, long paddle
€31.20 – €33.60Main uses: The most simple flow switch with magnetic pull-back. Recommended mounting position is on horizontal pipes, but can be mounted in any position. For water flow detection on dia. 25 to 63 mm water pipes.
-
Paddle flow switches, micro-switch contact, 1/2” BSPP male thread and Pt100 temperature sensor
Main uses: Water flow detection on water pipes with simultaneous water temperature measurement Functional principle: Balanced paddle, perpendicular to the main flow, actuating a micro- switch. Flexible elastomeric gasket between paddle and electric switch
-
Paddle flow switches, reed switch contact, built-in 16A SPDT relay
General application in flow detection. Recommended mounting position is on horizontal pipes, but can be mounted in any position. For water flow detection on dia 15 to 100mm water pipes. The built-in relay with SPDT contact can be used on resistive loads up to 15A 250V. The pilot light shows the contact position.
-
Paddle flow switches, reed switch contact, inside barbed tee for 1”soft tube
Main uses:Tee equipped with paddle flow switch, for spas and swimming pools applications, mounting on 1” (20 to 21mm ID) soft PVC tubes, adjustable setting. Used on water circulation circuits to detect the passage of water or filter clogging and avoid dry running. Recommended mounting position is on horizontal pipes, but can be mounted in…