Paddle flow switches, reed switch contact, external brass body

Main uses: General application in flow detection. . Recommended mounting position is on horizontal pipes, but can be mounted in any position. For liquids flow detection on dia. 15 to 100 mm pipes. Body and union nut in brass for improved mechanical strength and pressure resistance. Connection box with terminal block or connectors, and detection point adjustment screw

 

Flow sensing

Main housing material

Paddle material

Mounting position

Mounting type

Voltage

Electrical rating

Ingress protection

Electrical connection type

, ,

Maximum flow detection (L/min)

Minimum flow detection (L/min)

Calibration (gr)

, ,

Nominal pressure at 20°C

Max operating temperature (°C)

Liquids temperature range (°C)

Send an inquiry for this item
  • I agree that that the website retain and use my personal information to renew contact with me.
Insert a valid name
insert a valid mail
Insert message
Authorization needed to validate the form.

This product is currently out of stock and unavailable.

SKU: N/A Category:

Description

Size and pressure Flow sensing:

cleavable paddle

Mounting:

¾” BSPP Brass Union nut

Contact:

Reed switch, close on
flow rise

Electrical rating Mounting position Type
PN25

R1V

DN≥15

Dimensions

1: Paddle

2: ¾” BSPP Brass union nut and brass body

3: Connection box

4: Adjustment screw

5: EN17530-803-A (DIN43650-A)  connector (Option)

6: IEC947-5-2, M12x1, 4 terminals connector (Option)

Main uses: General application in flow detection. . Recommended mounting position is on horizontal pipes, but can be mounted in any position. For liquids flow detection on dia. 15 to 100 mm pipes. Body and union nut in brass for improved mechanical strength and pressure resistance. Connection box with terminal block or connectors, and detection point adjustment screw

Functional principle: Balanced magnetic paddle mounted perpendicular to the flow and activating a reed switch through the wall. The return of the paddle is by made by magnetic action, without spring. No seal or liquid can pass between the piping system and the electrical contact. Usable for industrial applications in non-corrosive liquids. Must not to be used for liquids containing magnetic particles or high viscosity liquids, which block the movement of the pallet.

Adjustment:

  • By cleaving the paddle
  • Fine adjustment by screw driver on internal dial

Paddle shaft: Titanium, providing an outstanding corrosion resistance, and improved mechanical live

Main housing material: Brass

Paddle: Polypropylene, 15 mm width, with 4 sections, numbered 1 to 4, can be cleaved for adjustment to pipe size

Pipe mounting: Nickel plated brass union nut,¾ BSPP, mounting on ¾ BSPP male thread with gasket.

Recommended torque: 10±1 Nm Gasket: NBR

Electrical rating: Max 1A, Max 70W, Max 250V, resistive load. Use on inductive circuits reduces electrical rating. We recommend to protect the reed switch with contact protection device when used in inductive loads

Electric contact type: Normally open, closes by flow rise

Liquids compatibility: For use with clean water and liquids without magnetic particles and without chemical incompatibility with brass, PPO and titanium

Nominal pressure at 20°C: 2,5 MPa (PN25)

Liquids temperature range: 5 to 100°C (Do not withstand water freez- ing inside pipe)

Ambient temperature range: 5 to 80°C

Ingress protection: IP65

Calibration tolerances: +/-15% (on paddle operating force at end of paddle 1)

Electrical connection:

Standard:

IP64 connection box, with screw terminal connection block, M16x1.5 ISO cable gland

Options:

  • Connection box with EN17530-803-A (DIN43650-A) connector
  • Connection box with IEC947-5-2 M12x1 4 pins connector

Installation instructions:

  • Check carefully the paddle orientation: The arrow on housing must be exactly parallel to the pipe
  • A 5 mm minimum gap must be respected between end of the paddle and tube wall opposite to the
  • We recommend the use of nozzles of length less than or equal to 18 mm between the gasket seat and the inside of the tube and with an inner diameter greater than or equal to 5 mm, to avoid blocking of the paddle.

Accessories: 3/4” male PVC saddles for DN40 to DN100 (OD) PVC pipes, and other fittings: see last section of this catalogue

Important notice: In the case of plastic pipes (PVC, PE), the DN (nominal diameter) corresponds to the outside diameter and wall thickness is variable depending on the application. This must be taken into account to avoid blocking the paddle. In the case of metal pipes, the inner diameter corresponds to the DN. Flow values data are for tubes whose internal diameter corresponds to DN.

Pipe mounting configurations

Average Flow detection values (Liters/min)

 

Paddle

length

Pipe ID (mm)
15 20 25 32 40 50 63 100
*Close **Open *Close **Open *Close **Open *Close **Open *Close **Open *Close **Open *Close **Open *Close **Open
1-m 2,7 2,3 4,8 4,5 13 11 22 20 38 35 67 47 167 112 472 317
1-H 4,3 3,3 7,3 6,5 18 17 29 27 53 48 83 72 218 142 616 401
1-M 5,5 3,2 14 12 25 22 38 35 67 60 132 108 262 202 740 571
1+2-m 20 18 37 32 68 52 192 155
1+2-H 30 28 53 43 88 72 248 203
1+2-M 40 37 67 63 123 115 347 324
1~3-m 22 20 37 33 125 108
1~3-H 34 32 63 50 176 165
1~3-M 46 43 77 73 233 217
1~4-m 27 24 88 72
1~4-H 43 40 140 132
1~4-M 58 55 180 167
m= calibration at min span

H= calibration at Half span

M= calibration at Max span

* Close by flow rise (L/min) of contact open at no flow position

** Open by flow decrease (L/min) of contact open at no flow position. Average values for indication only. Standard tolerances ±15%

 

Main references  (With type A cleavable paddle)

Calibration

(Calibration force ±15%, measured at

end of paddle N°1)

 

Waterproof connection box with M16x1.5 cable gland

Waterproof connection box with 4 pins, M12x1

IEC947-5-2  connector

 

Waterproof connection box with DIN 43650-A connector

Low span end: 3gr R1V636680G35N00C R1V636680G35N00L R1V636680G35N00D
Middle span:7gr R1V676680G35N00C R1V676680G35N00L R1V676680G35N00D
High span end:14 gr R1V6E6680G35N00C R1V6E6680G35N00L R1V6E6680G35N00D

Other paddles (Non cleavable models)

Paddle type B Paddle type C Paddle type D Paddle type E
Replace 6680 in reference by 1234 Replace 6680 in reference by 1549 Replace 6680 in reference by 1564 Replace 6680 in reference by 1579

 

Consult us for flow detection values with these paddles. OEM paddles can be made on order (MOQ apply)

 

Technical specifications sheet

TO ACCESS DOWNLOAD DOCUMENTS, PLEASE LOGIN/REGISTER. DATASHEET, DRAWINGS (.DWG), 3D MODELS (.STP) AND OTHER DOCUMENTS ARE AVAILABLE.