Additional thermostat shaft rotary switch, 20A 250-400V

Electronic thermostat, multi range, control and manual reset action, for incorporation, Pt100
48 x 48, Intelligent PID Temperature Controller, double display, multisensor, power relay and SSR output
€36.50
Reduced size: very small foot print allows it to replace any electromechanical thermostat.
Simple installation interface: auto-tune PID control, relay output and SSR output are standardized.
Simple storage and maintenance: one model covers all applications.
Weight | 0.25 kg |
---|---|
Dimensions | 48 × 48 × 74.4 mm |
Min storage temperature (°C) | |
Max storage temperature (°C) |
In stock
Description
Main features
Reduced size: very small foot print allows it to replace any electromechanical thermostat.
Simple installation interface: auto-tune PID control, relay output and SSR output are standardized.
Simple storage and maintenance: one model covers all applications.
Output percentage indication: with graphic LED bar.
Input: Pt100 and Thermocouples T, R, J, B, S, K, E, Wu3-Re25.
Output: relay output or voltage pulse.(field selectable)
Alarm: 1 alarm relay in standard. Second is an option.
Operation: auto-tune function sets automatically the PID parameters to the system characteristics.
Power supply voltage: AC 85~265V 50-60Hz (24VDC in option)
Power: <6W.
Output Specifications:
- Main Control Output: 1 relay, heating or cooling selectable,
- Contact Rating (SPST): 3A, 250Vac Res.
- Alarm output: 3A, 250Vac Res.
- SSR drive: 12V DC (20mA).
Communication: interface RS-485 in option.
Accuracy: 0.3%FS.
Dimensions: 48 x 48 x 74.4mm.
Panel cut-out: 45 x 45 mm.
Ambient Temperature: 0 to 50°C, 0 to 95% RH.
Reference: 244CUUB
Downloads
TO ACCESS DOWNLOAD DOCUMENTS, PLEASE LOGIN/REGISTER. DATASHEET, DRAWINGS (.DWG), 3D MODELS (.STP) AND OTHER DOCUMENTS ARE AVAILABLE.RELATED PRODUCTS
-
Electronic thermostat, multi range, control and manual reset action, for incorporation, NTC sensor
This electronic thermostat for incorporation has been designed to replace electromechanical thermostats. It is mounted with two screws M4 at the same distance 28 mm, uses a 6mm dia. shaft with 4.6mm flat with the same length, and its rotation angle is 230°. Therefor temperature ranges are quite the same as the bulb and capillary…
SIMILAR PRODUCTS
-
Adjustable manual reset electronic rod limiter IP66, IK10
- Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights. These electronic rod thermostats are installed inside pockets as immersion thermostats in pipelines and containers, and for monitoring temperature in air ducts. - Manual reset allows the use as high temperature…
-
Dia. 10mm cartridge thermostat 1/2″BSPT or M14x1.5 fitting, calibration from 50 to 120°C
Detection of a temperature value in liquids, water, hydraulic oils, thermal oils. Two versions of electrical contacts: Gold-plated for low power circuit, like PLC or 2A 250V for relay coils or resistive circuits.
-
Remote sensor electronic thermostat IP66, IK10
Applications -Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights. Temperature control with reduced differential, on-off action, in usual industrial applications and environments, not hazardous areas. Use of electronic sensor allows measurement at long distances, which is not possible with bulb…
-
Electronic rod thermostat temperature control IP66, IK10
Applications -Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights Temperature control with reduced differential, on-off action, in usual industrial application and environment, not hazardous areas. These electronic rod thermostats are installed inside pockets as immersion thermostats in pipelines and containers,…
-
Electronic temperature control, remote sensor, IP65
Applications Temperature control with reduced differential, on-off action, in usual industrial applications and environments, not hazardous areas. Internal adjustment is convenient for products that must not be frequently adjusted. Use of electronic sensor allows measurement at a long distance, which is not possible with bulb and capillary types.
-
Electronic thermostat, multi range, control and manual reset action, for incorporation, Pt100
This electronic thermostat for incorporation has been designed to replace electromechanical thermostats. It is mounted with two screws M4 at the same distance 28 mm, uses a 6mm dia. shaft with 4.6mm flat with the same length, and its rotation angle is 230°. Therefor temperature ranges are quite the same as the bulb and capillary…
-
Manual reset electronic rod limiter, IP65
Applications These rod limiters with electronic sensor with adjustable set point can be installed inside pockets as immersion high temperature limits on pipelines and containers, and for monitoring temperature in air ducts, in usual industrial applications and environments. (Not suitable for hazardous areas). Internal adjustment is convenient for products that must not be frequently adjusted.
Technical informations associated to this product
-
Description of temperature controls
Used as control thermostats or as a safety thermostat with manual reset, these thermostats have a disc made of two different metals laminated together for temperature sensing element. These two metals have different expansion coefficients. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies.